Source code for RsSmab.Implementations.Source.Frequency.Phase.Continuous

from .....Internal.Core import Core
from .....Internal.CommandsGroup import CommandsGroup
from .....Internal import Conversions
from ..... import enums


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
[docs] class ContinuousCls: """Continuous commands group definition. 4 total commands, 0 Subgroups, 4 group commands""" def __init__(self, core: Core, parent): self._core = core self._cmd_group = CommandsGroup("continuous", core, parent)
[docs] def get_high(self) -> float: """SCPI: [SOURce<HW>]:FREQuency:PHASe:CONTinuous:HIGH \n Snippet: value: float = driver.source.frequency.phase.continuous.get_high() \n Queries the maximum frequency of the frequency range for phase continuous settings. The maximum frequency of the frequency range depends on the mode selected with the command [:SOURce<hw>]:FREQuency:PHASe:CONTinuous:MODE. \n :return: high: float Range: 1E5 to 6E9, Unit: Hz """ response = self._core.io.query_str('SOURce<HwInstance>:FREQuency:PHASe:CONTinuous:HIGH?') return Conversions.str_to_float(response)
[docs] def get_low(self) -> float: """SCPI: [SOURce<HW>]:FREQuency:PHASe:CONTinuous:LOW \n Snippet: value: float = driver.source.frequency.phase.continuous.get_low() \n Queries the minimum frequency of the frequency range for phase continuous settings. The minimum frequency of the frequency range depends on the mode selected with the command [:SOURce<hw>]:FREQuency:PHASe:CONTinuous:MODE. \n :return: low: float Range: 1E5 to 6E9, Unit: Hz """ response = self._core.io.query_str('SOURce<HwInstance>:FREQuency:PHASe:CONTinuous:LOW?') return Conversions.str_to_float(response)
# noinspection PyTypeChecker
[docs] def get_mode(self) -> enums.FilterWidth: """SCPI: [SOURce<HW>]:FREQuency:PHASe:CONTinuous:MODE \n Snippet: value: enums.FilterWidth = driver.source.frequency.phase.continuous.get_mode() \n Selects the mode that determines the frequency range for the phase continuity. To query the frequency range, use the commands [:SOURce<hw>]:FREQuency:PHASe:CONTinuous:HIGH? and [:SOURce<hw>]:FREQuency:PHASe:CONTinuous:LOW? \n :return: mode: NARRow| WIDE NARRow Small frequency range, asymmetrically around the RF frequency. WIDE Large frequency range, symmetrically around the RF frequency. """ response = self._core.io.query_str('SOURce<HwInstance>:FREQuency:PHASe:CONTinuous:MODE?') return Conversions.str_to_scalar_enum(response, enums.FilterWidth)
[docs] def set_mode(self, mode: enums.FilterWidth) -> None: """SCPI: [SOURce<HW>]:FREQuency:PHASe:CONTinuous:MODE \n Snippet: driver.source.frequency.phase.continuous.set_mode(mode = enums.FilterWidth.NARRow) \n Selects the mode that determines the frequency range for the phase continuity. To query the frequency range, use the commands [:SOURce<hw>]:FREQuency:PHASe:CONTinuous:HIGH? and [:SOURce<hw>]:FREQuency:PHASe:CONTinuous:LOW? \n :param mode: NARRow| WIDE NARRow Small frequency range, asymmetrically around the RF frequency. WIDE Large frequency range, symmetrically around the RF frequency. """ param = Conversions.enum_scalar_to_str(mode, enums.FilterWidth) self._core.io.write(f'SOURce<HwInstance>:FREQuency:PHASe:CONTinuous:MODE {param}')
[docs] def get_state(self) -> bool: """SCPI: [SOURce<HW>]:FREQuency:PHASe:CONTinuous:STATe \n Snippet: value: bool = driver.source.frequency.phase.continuous.get_state() \n Activates phase continuity of the RF frequency. The frequency range is limited and varies depending on the set RF frequency. You can query the range with the commands [:SOURce<hw>]:FREQuency:PHASe:CONTinuous:HIGH? and [:SOURce<hw>]:FREQuency:PHASe:CONTinuous:LOW?. Note: Restricted structure of command line. In phase continuous mode, the R&S SMA100B only processes the first command of a command line and ignores further commands if they are on the same line. \n :return: state: 1| ON| 0| OFF """ response = self._core.io.query_str('SOURce<HwInstance>:FREQuency:PHASe:CONTinuous:STATe?') return Conversions.str_to_bool(response)
[docs] def set_state(self, state: bool) -> None: """SCPI: [SOURce<HW>]:FREQuency:PHASe:CONTinuous:STATe \n Snippet: driver.source.frequency.phase.continuous.set_state(state = False) \n Activates phase continuity of the RF frequency. The frequency range is limited and varies depending on the set RF frequency. You can query the range with the commands [:SOURce<hw>]:FREQuency:PHASe:CONTinuous:HIGH? and [:SOURce<hw>]:FREQuency:PHASe:CONTinuous:LOW?. Note: Restricted structure of command line. In phase continuous mode, the R&S SMA100B only processes the first command of a command line and ignores further commands if they are on the same line. \n :param state: 1| ON| 0| OFF """ param = Conversions.bool_to_str(state) self._core.io.write(f'SOURce<HwInstance>:FREQuency:PHASe:CONTinuous:STATe {param}')