Reference
SCPI Command :
TRACe<CH>:[POWer]:SWEep:PULSe:THReshold:POWer:REFerence
- class ReferenceCls[source]
Reference commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- get(trace=Trace.Default) float[source]
# SCPI: TRACe<CH>:[POWer]:SWEep:PULSe:THReshold:POWer:REFerence value: float = driver.trace.power.sweep.pulse.threshold.power.reference.get(trace = repcap.Trace.Default)
Queries the medial threshold level of the overall pulse level. This level is used to define the pulse width and pulse period. Note: This parameter is only avalaible in time measurement mode and R&S NRP-Z81 power sensors.
- param trace:
optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trace’)
- return:
reference: float Range: 0.0 to 100.0
- set(reference: float, trace=Trace.Default) None[source]
# SCPI: TRACe<CH>:[POWer]:SWEep:PULSe:THReshold:POWer:REFerence driver.trace.power.sweep.pulse.threshold.power.reference.set(reference = 1.0, trace = repcap.Trace.Default)
Queries the medial threshold level of the overall pulse level. This level is used to define the pulse width and pulse period. Note: This parameter is only avalaible in time measurement mode and R&S NRP-Z81 power sensors.
- param reference:
float Range: 0.0 to 100.0
- param trace: